That's a great way to lose the breaker though. If you're lucky the latch will fail. If you're unlucky it will weld shut.
reply
Not ideal, but it was the only thing that worked. This was attached to a million dollar piece of equipment, so any remedial electrical replacement work would have been slightly inconsequential. Thankfully, it was one of those machines that you turned off as infrequently as possible, so we did not have to do this procedure too many times.

The vendor did get the hint, and the second iteration of the device did slowly warm up the pumps so this process would no longer be required.

reply
Yes, soft start is the way to go. Also: proper industrial breakers allow for temporary overload. I have a couple of pieces of gear that have inrush currents well over the limit of a normal breaker so I put them on a slow one and now it is fine.

https://onccy.com/how-to-choose-between-type-a-b-c-and-d-min...

reply
> Also: proper industrial breakers allow for temporary overload

Notoriously a crescent wrench makes an excellent 1000A slow blow fuse

reply
A 5/32" flat-blade screwdriver makes an excellent fast-blow fuse when dropped across exposed bus bars. And you can re-use the remains of the handle to stir your coffee once you've retrieved it from across the room.
reply
Soft-start is in theory the way to go, but it's very dependent on the motor type, there's a whole pile of different methods required for induction motors depending on whether they're capacitor-start, permanent split capacitor, shaded-pole, etc, so you can do it in some cases by lowering the voltage, or with a VFD, or a VSD, or the old-fashioned way with a centrifugal switch but that requires very careful handling. If as the OP said it's running million-dollar equipment you probably don't want to monkey with it at that level.
reply
Reminds me of computer fans, some bioses seem to do that ramp up for no reason thing as well.
reply
You also want to be sure that, in the absense of fan-control, the CPU won't overheat. Full-on is safer than nothing until a driver is loaded.
reply
not exactly relevant to computer fans, but in case of your usual standing fan you need a way larger kick to get it going. if it fails to start but stays powered it will stay stuck, heat up and fail. this is why fans usually have the highest option as the first one, so you have to start it at full speed at first, and only then reduce it.
reply
deleted
reply
Fans have a minimum speed needed to spin up when cold starting from 0 RPM. So it's safer to start at near max RPM and spin down to the desired target RPM if the controller doesn't know the exact operating characteristics of each fan.

You can observe this with a speed control knob/ESP32 where a running fan will happily run forever with the knob turned down to e.g. a 30% duty cycle. But after turning to 0% and waiting for the blades to fully stop, if set back to the same 30% they won't move at all or you'll maybe hear a sketchy clicking/whine sound with the blades intermittently twitching.

reply
I've always assumed it was to calibrate the PWM sensor for fan speed, so it starts with no sensing active, runs up to max, and then the sensor kicks in and settles it down. You don't need to run a fan at max speed to get it to start, most will start with very little power applied.
reply